Search results for “Chest x-ray

About 2 results in articles

Open Access Pub publishes peer-reviewed, free-to-read open-access articles. Showing articles matching Chest x-ray — open any to read the full text, or download the PDF or XML.

2 articles

Entrance Surface Dose (ESD) Measurement During Pediatric Chest X-Rays

Nov 2020 DOI 10.14302/issn.2766-8630.jrnm-20-3288
Maraei AsmaCorresponding author Department of Medical Engineering, School of Technical and Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran

Introduction Given the high radiation tissue sensitivity of pediatric patients, it is necessary to monitor their received dose in order to optimize radiation protection. The first aim of this study was to evaluate of the entrance surface dose (ESD) in pediatric patients undergoing chest x-ray at the main hospital of Dezful, Iran. The second aim was to compare our results with the established dose reference levels (DRL). Materials and Methods The studied population included 204 pediatric patients less than 15 year who were referred to chest x-ray. A calibrated dose area product meter (DAP-meter) with permanent installation on x-ray unit was used to radiation dose measurements. For each patient, the demographic data, exposure parameters and the dose read by DAP-meter were recorded and ESD was calculated using standard mathematical formula. Results The average value of ESD was 119 μGy in patients less than 15 years. This value was 51.3, 122.3, 131.5 and 171.2 μGy for the age groups less than 1 year, 1 to 5 year, 5 to 10 year and 10 to 15 year, respectively. A statistical significant difference was seen between ESD values ​​in different age groups (P<0.001), whereas no statistical difference was seen between ESD values in ​ girls and boys (P =0.993). Conclusion Pediatric patients in hospital investigated (except age group less than 1 year) are subjected to unnecessary radiation exposure, especially due to use of non-optimize x-ray protocols.

‘A perfect Example of the Strong Ion Difference: Hyperchloraemic Acidosis due to 0.9% Normal Saline Irrigation, in a Patient with a Ruptured Bladder’

Jul 2019 DOI 10.14302/issn.2641-5518.jcci-19-2909
Lane AndrewCorresponding author Sydney Medical School, University of Sydney

An 81-year-old male presented to the Emergency Department with urinary retention, subsequent to passing blood clots. A three-way catheter was inserted for continuous bladder irrigation. 48 hours later he deteriorated, with worsening tachypnea and hypoxaemia. Clinical examination and chest x-ray suggested pulmonary odema, managed with intravenous furosemide, and non-invasive ventilation. His irrigation circuit-chart showed he had received 10 litres Normal Saline via the afferent limb, but only 3 litres recorded at the efferent limb. It was suspected the catheter was adjacent to a vascular-cystic interface, however an urgent contrast CT revealed the irrigating catheter perforating the bladder, being situated in the abdominal cavity (see 3 images). His arterial blood-gas analysis demonstrated the expected normal anion-gap academia, however his Strong Ion Difference calculations, sodium-chloride difference of 13 and a normal albumin level, perfectly demonstrated the expected calculated BE of -13. The catheter was withdrawn, and the patient made a full recovery.

Frequently asked questions

Are these articles peer-reviewed?
Yes. Articles published at Open Access Pub go through single-blind peer review (double-blind on request) under an editorial board before publication.
Are the articles free to read?
Yes. Every article is open access — read the full text online for free and download the PDF or XML, with no paywall or subscription.
How do I cite an article?
Use the DOI shown on each result and on the article page; it is the permanent, citable link to the article.
How do I read or download an article?
Click "Read full text" to open the article HTML, or use the PDF / XML buttons on each card to download it.